Abstract
frequency dependence of the Kerr constant K in transformer oil Nynas Nytro 3000 within a frequency range 117-5017 Hz is determined. An averaged value (2.30 ± 0.03)·10-15 m/V2 for K is obtained. The constant is found to be weakly frequency dependent and approaches its maximum 2.37·10-15 m/V2 at about 3000 Hz. The Kerr constant is of comparable value to that observed in other mineral oils employed previously in measurements of the quadratic electro-optic effect and the electrostriction in crystals.
References
Kerr J. 1875. A new relation between electricity and light: Dielectrified media birefringent. Philosophical Magazine 50 (332): 337-348.
Born M., Wolf E. 1975. Principles of Optics, 5th edition, Oxford: Pergamon Press.
Ratajczyk F. 2000. Dwójłomność i polaryzacja optyczna, Wrocław: Oficyna Wydawnicza Politechniki Wrocławskiej.
Ledzion R., Bondarczuk K., Górski P., Kucharczyk W. 1999. Kerr constants of some mineral and silicone oils. Quantum Electron. 29: 739-741.
Górski P., Ledzion R., Sadowski M., Kucharczyk W. 2009. Effect of temperature on the refractive index and Kerr effect of the transformer oil NYNAS Nytro Taurus. Sci. Bull. Techn. Univ. Lodz, Physics, 30: 29-34.
Gunning M.J., Raab R.E., Kucharczyk W. 2001. Interferometric measurements of electrostrictive coeffiecients of KDP and ADP in Transmission. Ferroelectric Letters 28: 93-102
Kucharczyk W., Ledzion R., Górski P. 2014. The effect of aging of transformer oil on the magnitude and temperature dependence of its Kerr constant. Przegląd elektrotechniczny (Electrical Rev.) 12: 40-42.
Izdebski M., Ledzion R., Kucharczyk W. 2017. Application of polarimetric technique for determining the sign of quadratic electro-optic coefficients in crystals. J. Opt. Soc. Amer. B 34: 2281-2286.
http://www.ms-oil.ch/media/files/002/0022002.pdf
Izdebski M., Ledzion R. 2017. Kerr constant measurement technique for liquids exhibiting orientational ordering of molecules. Optik 140: 812-822.